Number: Date: 23-Aug-84 17':03':22 Submitter: Sybalsky Source: Sybalsky Subject: PRINT, QUERY during scroll of AR Query window loses -- need interlocks Assigned To: Attn: Sannella Status: Fixed In/By: Problem Type: Bug Impact: Annoying Difficulty: Frequency: Everytime Priority: System: Text Subsystem: Other Machine: 1132 Disk: Lisp Version: 22-Aug-84 00':45':52 Source Files: Microcode Version: 5124 Memory Size: 4096 File Server: Server Software Version: Disposition: ' ["Sannella.PA" "23-Aug-84 19':01':30" Status':(New->Open) System':(Other% Software->Text)]' ["Sannella.PA" "28-Aug-84 11':27':47" Subject': Description':]' ["Sannella.PA" "30-Aug-84 11':34':21" Status':(Open->Fixed)] Description: And seems to stop the Print, so you only get a partial file, as well.' ' -----' ' Date': 22 Aug 84 14':57 PDT' From': masinter.pa' Subject': I can''t seem to have two AR query browsers open at once' To': LispSupport' ' If I do a query in one window while scrolling the other, I get things like "70949" as the ar number, and END OF FILE {PHYLUM}AR.INDEX in another.' Workaround: Test Case: Edit-By: Sannella.PA Edit-Date: 30-Aug-84 11':34':22