Number: 1259 Date: 30-May-84 15':24':12 Submitter: vanMelle Source: vanMelle Subject: Incomplete spelling correction in Mastercope file noticer Lisp Version: 21-May-84 01':21':39 Description: ' I had done a LOADFROM(MOD44IO). I then said' . ANALYZE ON MO44IO' to which someone responded' =MOD44IO' ' Fine, I thought, but then Masterscope proceeded to print "Can''t analyze x" for all functions on the file. It did the same thereafter even when I correctly spelled MOD44IO.' ' A little investigation revealed that MSFILELST contained ((MOD44IO . MO44IOCOMS)), i.e., the misspelled version of MOD44IO packed with COMS instead of the correct spelling. Naturally, INFILECOMS? failed on the misspelled coms. Setting MSFILELST to NIL cured the problem.' Workaround: Test Case: Edit-By: Edit-Date: 30-May-84 15':24':12 Attn: Masinter Assigned To: In/By: Disposition: System: Programming Environment Subsystem: Masterscope Machine: 1132 Disk: Microcode Version: 5124 Memory Size: 4096 File Server: Server Software Version: Difficulty: Moderate Frequency: Once Impact: Moderate Priority: Perhaps Status: Open Problem Type: Bug Source Files: