<> <> <<>> MasterControl: Off => don't respond to events Manual => respond to events by printing them Auto => respond to events with appropriate action PrintHelp Button: Tells you about this document. StatusAll Button: red, yellow, blue => Aquire status and GV data for each Lark blue => set debugging pointers shift => print status in log ResetAll Button: Same as the individual Reset buttons, but for each Lark. StartAll Button: Aquire status from each lark and consider automatic load. Always sets debugging pointers. shift => print status in log NewSoftware Button: Re-Parse all loaded Lark software. Does not reset the program pointers of any Larks. Use StatusAll for that. Load Button: Get lark status. Will not load a "running" Lark. red, yellow => load previous program blue => start lark at program start address shift => start after loading Reset Button: red => please enter debugger yellow => please hardware reset blue => both Mode Button: red, yellow => set mode and program from grapevine blue => enter debug mode, GV override Debug Button: toggle work area Status Button: red, yellow => print remote status blue => print remote status and set debugging pointers