0 1BoardBlank.msgs - last edit: Ashwin 26-Feb-86 11:13:42 1 1Values greater than %u are prohibited %s.%n 2 1Duplicate values are prohibited %s.%n 3 1%u is an invalid entry %s; values must be consecutive starting with 1.%n 4 1There is nothing %s; at least one entry is required.%n 5 1Couldn't get index for something %s; tables probably misaligned.%n 6 1Part placed.%n 7 1The board has multiple origin points; this is not allowed. [0, 0] will be used as the origin.%n 8 1Validating new board %s ...%n 9 1Validating old board %s ...%n 10 1... done.%n 11 1... failed; warnings issued; board not written.%n 12 1%u graphic objects changed to aperture %u.%n 13 1The selected rectangle is invalid.%n 14 1There is no board outline.%n 15 1The board outline is not clustered.%n 16 1The board outline is not closed.%n 17 1No placement rectangle has been specified; this is not allowed.%n 18 1Discovered field with bad properties %s.%n 19 1No entry in %s.%n 20 1Invalid aperture number specified %s.%n 21 1Must be draw aperture %s.%n 22 1Missing field %s.%n 23 1The number %s must be the maximum layer number -- it is too small.%n 24 1Must be a round aperture %s.%n 25 1The number %s must be the maximum layer number -- it is too large.%n 26 1Must be a flash aperture %s.%n 27 1The last number %s must be the last etch rule.%n 28 1The number %s must equal the number %s.%n 29 1There is no user specified origin; [0, 0] will be used as the origin.%n 30 1The part connect and part no-connect pad stack tables are of different lengths; they must be the same length and must define the same pad stack codes.%n 31 1Stack %u is defined in the part connect pad stack table but is not defined in the part no-connect pad stack table.%n 32 1A stack (%u) is not defined in the pad stack tables, but is needed by a part.%n 33 1The line styles for %s have been set according to the aperture table.%n 34 1Creating checkplot %s.%n 35 1The checkplot drawing has the wrong number of layers in the %s; it should have %u layers.%n 36 1Creating photoplots %s.%n 37 1The text field %s was empty; it must contain a numeric value.%n 38 1There is a zero index %s; this is not allowed.%n 39 1A single point should be selected.%n 40 1The selected box has a negative x or positive y coordinate; this is not allowed.%n 41 1The outline has a negative x or positive y coordinate; this is not allowed.%n 42 1The origin has a negative x or positive y coordinate; this is not allowed. [0, 0] will be used as the origin.%n 43 1A part has a negative x or positive y coordinate; this is not allowed.%n 44 1There is a bad layer in the layer table.%n 45 1Origin point already exists.%n 46 1One of the rectangles has sides not all of whose line styles are the same; this is not allowed.%n 47 1More than one placement rectangle has been specified; this is not allowed.%n 48 1One of the sides of the outline does not have a line style of board.%n 49 1Reference designator must be set.%n 50 1No message.%n 51 1Validate failed.%n 52 1The photoplot %s contains %u invalids.%n 53 1The photoplot %s contains %u incompletes. The incompletes were not plotted.%n 54 1Invalid aperture number specified %u.%n 55 1Silkscreen text height field was not filled in.%n 56 1Silkscreen text height field was missing.%n 57 1An non-null aperture > 24 (#%u) was defined in the aperture table. This is not permitted.%n 90 1Internal error during board validation.%n 100 10,Aperture,Size,Shape,Type,Etch Rule,Part Connect Pad Stack,Pad Stack Code,Solder Mask,Pad Master,Hole Size,Layer,Part No-Connect Pad Stack,Via Connect Pad Stack,Via No-Connect Pad Stack,Clearance,Etch Rule Column,Silkscreen Text Aperture,Silkscreen Shape Aperture,Silkscreen Text Height,Vias Allowed Under Parts,Spare 1,Spare 2,Spare 3,Spare 4,Spare 5,Spare 6,Spare 7,Spare 8,in the,column,of the,table,in row 200 10,Etch,Layer,Complete,Invalid,Incomplete,Global Incomplete,Pads,PadMaster,Top solder mask,Bottom solder mask,Part pads,Via Pads,Holes,Size,No-etch top,No-etch bottom,No-etch interior,No-place,No-route,Etch-top,Etch-bottom,Board outline,Reference designators,Silkscreens,Component shapes,Junctions,Spare 1,Spare 2,in the,column,of the,table,in row 1999 1Keeps MsgImpl from reading off the end looking for the last message.%n