0 Schematics.msgs - last edit: McMaster 2-Jan-85 11:15:35 1450 1The Source Marker and Destination Marker aren't on the same page!%n 1451 1Selection by box only allowed on the page containing the source and destination markers!%n 1452 1The symbol does not have any definition.%n 1453 1This view is now on the first page of the symbol's definition.%n 1454 1Edit the path in a view that contains the selection.%n 1455 1IMPLEMENTATION INCONSISTENCY DETECTED!%n 1456 1Nothing has been selected.%n 1457 1Too many elements selected.%n 1458 1Selection is not a component.%n 1459 1Selection is not a junction.%n 1460 1Selection is not a net.%n 1461 1Selection is not a pin.%n 1462 1Selection is not text.%n 1463 1Selected text is not a valid id.%n 1464 1Selected text is a valid id but is not defined in the library!%n 1465 1Selected text is a defined but invalid id.%n 1466 1No shape exists for this schematic's grid & template.%n 1467 1Selected text is a valid id, but is not a logic symbol.%n 1468 1Must select multiple items to create cluster.%n 1469 1Some of selected items in old clusters. Deleted from old clusters.%n 1470 1After removable of that element, only one item remained in the cluster. The one item cluster has been deleted.%n 1471 1Selected item not contained in any clusters.%n 1472 1Property Sheet is unavailable when there is no selection.%n 1474 1Property Sheet is unavailable during Add To Selection.%n 1475 1Last page that will be expanded is %u.%n 1476 1The schematic appears to have been previously expanded.%n 1477 1, page %u to page %u 1478 1Copying pages containing hierarchy that will be expanded.%n 1479 1Page %u to page %u 1480 1.%n 1481 1Beginning expansion ... %n 1482 1There is no hierarchy to expand.%n 1483 1... expansion complete.%n 1484 1Connectivity symbol on definition page references pin %s, but that pin is not on any net.%n 1485 1ExpandPage: nextFreePage is %u, expansionDepth is %u.%n 1486 1Copying page %u to page %u and expanding.%n 1487 1Missing suffix found on new page %u; continuing ...%n 1488 1Suffix with non-numeric characters found on new page %u; continuing ...%n 1489 1No match for pin %s found while expanding page %u.%n 1490 1Removing definition at depth %u 1491 1 ... components 1492 1 ... lines 1493 1 ... text 1494 1 ... netChunks 1495 1 ... components (again) 1496 1 ... done.%n 1497 1Fix up nets: %u.%n 1498 1MaybeExpandPage: nextFreePage is %u , expansionDepth is %u.%n 1499 1 ... deleting netChunk 1500 1 ... replacing with logical connectors 1501 1 ... deleting definition 1502 1Selection is empty.%n 1503 1Move operation is not implemented between two schematics.%n 1504 1Schematics must have the same grid and template values. Copy aborted.%n 1505 1The Destination Marker was too close to the edge of the page to move!%n 1506 1The requested MOVE across pages requires a connectivity symbol. MOVE cancelled.%n 1507 1The requested operation would place items beyond the schematic boundaries.%n 1508 1Selection may not span multiple pages; operation aborted.%n 1509 1The selection and the source marker must be on the same page; operation aborted.%n 1510 1Please specify the destination.%n 1511 1Further operations will not be replayable. I suggest that you save your design.%n 1512 1The requested operation would place items beyond the schematic boundaries.%n 1513 1Edit Net with empty edit did nothing.%n 1514 1You have left the page you started on!!%n 1515 1Coordinate matches last coordinate specified. Ignored.%n 1516 1Update net path on page containing path to be edited.%n 1517 1Cannot delete after net path updated. Abort edit and retry path edit to delete.%n 1518 1You cannot delete critical connectivity symbols.%n 1519 1Finish the present operation before bringing up Schematic Tool Properties!%n 1520 1You must close the existing Schematic Tool Properties window first!%n 1521 1You must close the existing Output Options window first!%n 1522 1Probing the network for output servers ... 1523 1 no servers responded!%n 1524 1 done.%n 1525 1Drawing dimensions incorrectly specified.%n 1526 1You aren't editing the schematic so the property grid, drawing size, discrete device parameters, and font items are not modifiable.%n 1527 1You aren't editing the schematic so the page id and property grid items are not modifiable.%n 1528 1%u symbols replaced on loading. Read aborted.%n 1529 1Schematic does not appear to match library. Please see your System Administrator.%n 1531 1Cannot Apply the property sheet with zero length text string.%n 1532 1Specified format is not yet implemented.%n 1533 1done.%n 1535 1Please specify an output server.%n 1536 1This workstation is not connected to a local plotter.%n 1537 1This window cannot be deactivated.%n 1538 1Formatting ... 1539 1Plotter not available. Output aborted.%n 1541 1formatting ... 1542 1Click the left mouse button to confirm.%n 1543 1You have reached an opportunity to go to the debugger.%n 1544 1save changes and close 1545 1The backwards slash(/) cannot be placed at the end of the net name since it is used in the net list to represent negated nets.%n 1546 1Aborted by user.%n 1547 1 ... aborted by user.%n 1548 1file %s.cal925 created, 1549 1file %s.cal945 created, 1550 1file %s.hp7580 created, 1551 1file %s.hp7585 created, 1552 1file %s.comp80 created, 1553 1file %s.VRF created ... 1554 1 use RS232C Tool to send.%n 1555 1 use Tape Tool to send.%n 1556 1Outputting schematic ... 1557 1file %s.pub created.%n 1558 1file %s.hp7475 created, 1559 1Encountered instance of symbol %u on page %u which has pin %u connected to net (name: %s, number: %u), but 1560 1pin %u is now at that position.%n 1561 1Click the left mouse button to confirm connecting the net to pin %u, click the right mouse button to leave the pin and net inconsistent.%n 1562 1there is no longer a pin at that position. Continuing...%n 1563 1%u connections to symbol pins inconsistent with current library. Please examine the edit log and fix these problems before continuing.%n 1564 1%u connections to symbol pins switched to match current library. Schematic must be edited and saved to retain these updates.%n 1565 1Verifying that pin and net positions are consistent...%n 1566 1pins and nets are consistent.%n 1567 1Schematic is too large to fit in specified graphics frame.%n 1568 1Must set scale to %s for the schematic to fit.%n 1569 1Schematic cannot be scaled to fit in graphics frame.%n 1570 1Unnamed nets cannot be negated.%n 1571 1file %s.houstonI created, 1600 1Conflicting logic uniqueness designators exist: 1601 1 %s 1602 1; hence page continues to define the OLD id.%n 1603 1The Symbol Designator must have at most %u characters.%n 1604 1Another symbol in your design is designated as: %s.%n 1605 1Click the left mouse button to confirm 1606 1Old net is still using net number %u.%n 1607 1using the first unused net number, %u.%n 1608 1Must 'Apply to whole net' to change net number of named net.%n 1609 1Net number is being set to 32767.%n 1610 1using this default value.%n 1611 1Net number is being set to 0.%n 1612 1using this value.%n 1613 1merging the net named %s into the net named %s.%n 1614 1merging this net piece into the existing net named %s.%n 1615 1Must 'Apply to whole net' to change net number without changing name.%n 1616 1Schematic has an unnamed net which already uses net number %u.%n 1617 1Schematic has a net named %s which already uses net number %u.%n 1618 1using the first unused net number, %u.%n 1619 1The net named %s already uses net number %u.%n 1620 1There is already a net named %s but its net number is %u.%n 1621 1merging these nets.%n 1622 1merging this net piece into the existing net.%n 1623 1There is already a net named %s in the schematic, with net number %u.%n 1624 1There is also a net numbered %u in the schematic, with net name %u.%n 1625 1There is also a net numbered %u in the schematic, that is unnamed.%n 1626 1Only named nets can have several pieces, and this number collides with the existing net named %s.%n 1627 1Only named nets can have several pieces, and this number collides with another unnamed net.%n 1628 1Only named nets can have several pieces.%n 1629 1There is another net named %s that does not have any connectivity symbols,%n and the net to be changed does not have any connectivity symbols.%n 1630 1There is another net named %s that does not have any connectivity symbols.%n 1631 1There is another net named %s, and the net to be changed does not have any connectivity symbols.%n 1632 1Remainder of cluster also deleted.%n 1633 1There are no components on this page.%n 1634 1Do one page at a time, with connectivity symbols. Pin on this page ignored.%n 1635 1Closest junction is full!%n 1636 1Net removed from cluster as a result of edit.%n 1637 1Can't merge nets with different names.%n 1638 1Can't merge more than 2 nets at once.%n 1639 1Create/Modify Net with empty net did nothing.%n 1640 1Can't make a net with only one connection point selected.%n 1641 1The font you specified for %s is NOT available.%n 1642 1Selection is not in a schematic!%n 1643 1The last item you deleted was not from the schematic.%n 1644 1You cannot paste items from another schematic.%n 1645 1You've already pasted the last items you deleted.%n 1646 1The net number and net name have been changed.%n 1647 1The deleted net could not be reinserted because the attached symbols have been changed.%n 1648 1A net in the deleted data could not be reinserted into the schematic.%n 1649 1The deleted data cannot be restored!%n 1650 1Requested operation cannot be attempted until current operation is completed.%n 1651 1The schematic has not yet been made editable.%n 1652 1%n 1653 1Source marker cannot be moved manually during replay.%n 1654 1Destination marker cannot be moved manually during replay.%n 1655 1No operation to AGAIN.%n 1656 1Unexpected replay step encountered. No action taken.%n 1657 1Unexpected Selection. Replay step ignored.%n 1658 1Replay is complete.%n 1659 1Symbol was not found in the schematic.%n 1660 1Net was not found in the schematic.%n 1661 1Pin was not found in the schematic.%n 1662 1The schematic is not open. Please open the schematic and try again.%n 1663 1The schematic is locked. Please terminate net editing.%n 1664 1Replay step did not succeed.%n 1665 1You cannot delete critical connectivity symbols.%n 1666 1Selection operation not yet implemented.%n 1667 1Interchange file cannot be output while the schematic is being edited.%n 1668 1Ascii dump file %s created.%n 1669 1Formatting output pages ... 1670 1%u 1671 1The schematic is not editable.%n 1672 1No insertion place exists.%n 1673 1No characters in the insertion string.%n 1674 1Please confirm back annotate by clicking the left mouse button, or abort by clicking the right mouse button.%n 1675 1Are you still sure?%n 1676 1EditSchematic must be selected prior to BackAnnotate command.%n 1677 1Aborted.%n 1678 1The file to be back annotated from is missing.%n 1679 1The Back Annotation file and the schematic do not match. Suggest that you discard edits and double check that the back annotation file pertains to this schematic.%n 1680 1Done.%n 1681 1The interface is not supported.%n 1682 1Back Annotation could not be done due to an unknown problem.%n 1683 1Edit path and junctions with empty edit did nothing.%n 1684 1Coordinate matches last coordinate specified. Ignored.%n 1685 1Updating the net path must be done on page containing path to be edited.%n 1686 1Delete cannot be done after net path has been edited.%n Please abort and restart the command to delete a segment of the net path.%n 1687 1You cannot delete critical connectivity symbols.%n The whole net path must be deleted or renamed before this connectivity symbol can be deleted.%n 1688 1Pins are on Off-Page Connectors with DIFFERENT names.%n 1689 1Setting net name to be: %s.%n 1690 1Pin is on an Off-Page Connector with a DIFFERENT name.%n 1691 1There is another net named %s, but it has no connectivity symbols.%n 1692 1Unable to construct a net with the pins you specified.%n 1693 1There are no PINS on this page.%n 1694 1Remainder of cluster also deleted.%n 1695 1Your connection would create a loop in an existing net!%n 1696 1Merge not allowed as the connection would join two nets with different names!%n 1697 1Your connection would connect a pin to itself!%n 1698 1Net removed from cluster as a result of edit.%n 1699 1You have left the page you started on!%n 1700 1You have not yet specified anything to Apply.%n 1701 1You haven't yet specified any bend points.%n 1702 1Ignoring coordinate as it matches last coordinate specified.%n 1703 1The connection you are defining must stay on one page.%n 1704 1You haven't done anything yet to UNDO.%n 1705 1You are NOT over the page you started on.%n 1706 1Symbol %u not found in library. Replaced with safe symbol to avoid crash.%n 1707 1Library does not exactly match schematic, checking for problems ... 1708 1%u symbol instances were replaced.%n 1709 1No problems encountered.%n 1710 1Reading schematic ... page: 1711 1Schematic has old format: converting it (schematic must be edited and saved to retain this conversion) ... page: 1712 1Schematic is not of type binary. Please see your System Administrator.%n 1713 1The connectivity symbol required to repair the schematic cannot be found in your library. Please see your System Administrator.%n 1714 1The library file is damaged. Please see your System Administrator.%n 1715 1There is no system library. Please see your System Administrator.%n 1716 1Schematic has obsolete format. Please see your System Administrator.%n 1717 1Schematic has unknown format (possibly due to file damage). Please see your System Administrator.%n 1718 1Format 1719 1%u 1720 1 ... clusters 1721 1 ... done.%n 1722 1Encountered cluster that contains a missing node.%n 1723 1Schematic already open.%n 1724 1The schematic is not presently open.%n 1725 1You must either Discard or Save your edits before doing a Close!%n 1726 1Cannot perform Close! due to unknown system failure.%n 1727 1You cannot 1728 1 while in the middle of an operation.%n 1729 1Close 1730 1create another view 1731 1save changes 1732 1erase changes 1733 1destroy a view 1734 1erase changes and close 1735 1back annotate 1736 1Click the left mouse button to confirm overwriting the old design.%n 1737 1Click the left mouse button to confirm discarding edits.%n 1738 1Only net name object properties can be copied.%n 1739 1Edits only occur when you click down and release the mouse inside a window.%n 1740 1A group of items that includes an object property cannot be copied.%n 1741 1Operations on object properties are not replayable. I suggest that you save your design.%n 1742 1The last operation may have moved or copied object properties improperly. I suggest you check your design carefully.%n 1743 1The format of this schematic was updated while it was being opened. I suggest that you edit and save this design to retain the updates.%n 1744 1There is no path on this net to edit. Command aborted.%n 1751 1Problems encountered trying to open the file: %s%n 1752 1Reading the file: %s 1753 1Problems encountered trying to open the From file. %n 1754 1. 1755 1Back Annotating From Computer Vision File: %s%n 1756 1Board has old format. Please convert it and retry this command. %n 1757 1Board cannot be opened.%n 1758 1Back annotating using Place and Route information ... 1759 1 Done.%n 1760 1Placement contains %u symbols that are no longer in the schematic. Back annotation could not be done with them.%n 1761 1 Schematic contains %u unplaced symbols. These symbols not back annotated.%n 1900 1Internal confusion - edit log is not open; proceeding anyway!%n 1901 1Internal confusion - schematic is not being edited; proceeding anyway!%n 1902 1Saving your edits ... page: 1903 1 ... safe and sound.%n 1904 1Discarding your edits ... 1905 1Your edits have been discarded. You may now proceed.%n 1906 1Internal confusion - schematic is not open; proceeding anyway!%n 1907 1Cannot reread schematic while other tools are accessing database. Please stop other operations and try again.%n 1908 1Deletion displayed. Please apply or abort delete to resume edits.%n 1909 1Both source and destination markers must be on the same page.%n 1910 1Cannot create line with zero length.%n 1911 1There is another net named %s. Please add a connectivity symbol to your net.%n 1912 1No net found to name.%n 1913 1Name Component has not yet been implemented.%n 1914 1Cannot rename a net containing a named logical or physical connector.%n 1915 1Property is meaningless for extended selection.%n 1916 1The Reference Designator must have at most 10 characters.%n 1917 1Specified rotation and mirroring of symbol has not been defined in the library.%n 1918 1Rotation and mirroring indicated maps to library entry with different pin count.%n 1919 1Line width incorrectly specified.%n 1920 1Only horizontal or vertical lines supported.%n 1921 1Cannot create line with zero length.%n 1922 1Cannot create line which goes outside border of page.%n 1923 1Apply failed!%n 1924 1Property sheet aborted.%n 1925 1MOVE only supported for a property sheet for a NET.%n 1926 1Which occurrence of the net name do you mean?%n 1927 1Source and destination must be supplied for MOVE.%n 1928 1COPY only supported during a property sheet for a NET%n 1929 1You haven't specified where to place the copy of the net name!%n 1930 1You haven't given a name to this net yet!%n 1931 1DELETE only supported for a property sheet for a NET.%n 1932 1You can only DELETE an occurrence of the net name.%n 1933 1Paste not supported when property sheet up.%n 1934 1Cannot bring up two property sheets at once.%n 1935 1Expand not supported when property sheet up.%n 1936 1Selection must be an occurrence of the net name.%n 1937 1Cannot have pins or object properties in cluster. Command aborted.%n 1938 1You cannot delete object properties or pins.%n 1939 1You have specified an invalid value.%n 1940 1Specified value (%s) will be rounded to %s. 1941 1Object properties don't have properties TODAY.%n 1942 1Delete operation is not valid between two schematics.%n 1943 1Object properties can not be copied to another schematic.%n 1944 1Can not move or copy net chunks from format page to logic page.%n 1945 1The DELETE key is not supported for this mode.%n 1946 1The AGAIN key is not supported for this mode.%n 1999 1This message is put in to keep MsgImpl from reading off the end of the file looking for the last message.