-- Stub file  was translated on July 19, 1984 2:05:37 am PDT by Lupine of December 20, 1983 1:22:57 pm PST
-- Source interface Multibus came from file Multibus.bcd, which was created on July 19, 1984 1:56:38 am PDT with version stamp 14#17#25044235147 from source of July 17, 1984 3:41:14 pm PDT.

-- The RPC stub modules for Multibus are:
--   MultibusRpcControl.mesa;
--   MultibusRpcClientImpl.mesa;
--   MultibusRpcBinderImpl.mesa;
--   MultibusRpcServerImpl.mesa.

-- The parameters for this translation are:
--   Target language = Cedar
--   Default parameter passing = VALUE
--   Deallocate server heap arguments = TRUE
--   Inline RpcServerImpl dispatcher stubs = TRUE
--   Declare signals = TRUE
--   Warn about short POINTER ("MDS") allocations = TRUE
--   Maximum number of dynamic heap NEWs = 50, MDS NEWs = 50
--   Acceptable parameter protocols = VersionRange[1..1].


DIRECTORY
  Multibus,
  RPC USING [defaultInterfaceName, EncryptionKey, InterfaceName, Principal,
      standardZones, VersionRange, Zones];


MultibusRpcControl: DEFINITIONS
  SHARES  Multibus
  = BEGIN OPEN Multibus, RpcPublic: RPC;


-- Public RPC types and constants.

  InterfaceName: TYPE = RpcPublic.InterfaceName;
  VersionRange: TYPE = RpcPublic.VersionRange;
  Principal: TYPE = RpcPublic.Principal;
  EncryptionKey: TYPE = RpcPublic.EncryptionKey;
  Zones: TYPE = RpcPublic.Zones;
  
  defaultInterfaceName: InterfaceName = RpcPublic.defaultInterfaceName;
  standardZones: Zones = RpcPublic.standardZones;


-- Standard remote binding routines.

  ImportInterface: SAFE PROCEDURE [
        interfaceName: InterfaceName ← defaultInterfaceName,
        parameterStorage: Zones ← standardZones ];

  UnimportInterface: SAFE PROCEDURE;

  ExportInterface: SAFE PROCEDURE [
        interfaceName: InterfaceName ← defaultInterfaceName,
        user: Principal,
        password: EncryptionKey,
        parameterStorage: Zones ← standardZones ];

  UnexportInterface: SAFE PROCEDURE;


-- Dynamic instantiation and binding.

  ImportNewInterface: SAFE PROCEDURE [
        interfaceName: InterfaceName ← defaultInterfaceName,
        parameterStorage: Zones ← standardZones ]
    RETURNS [interfaceRecord: InterfaceRecord];

  -- NewInterfaceRecord is necessary for Cedar clients who want to
  -- manufacture a private interface instance, because
  -- RpcBindingImpl has finalization on type InterfaceRecord.
  NewInterfaceRecord: SAFE PROCEDURE
    RETURNS [interfaceRecord: InterfaceRecord];

  InterfaceRecord: TYPE = REF InterfaceRecordObject;

  InterfaceRecordObject: TYPE = RECORD [
      Error: ERROR [reason: LONG STRING],
      Input: PROCEDURE [address: HANDLEIOAddress] RETURNS [word: UNSPECIFIED],
      Output: PROCEDURE [word: UNSPECIFIED, address: HANDLEIOAddress],
      RawRead: PROCEDURE [address: HANDLERawAddress] RETURNS [word:
          UNSPECIFIED],
      RawWrite: PROCEDURE [word: UNSPECIFIED, address: HANDLERawAddress],
      RawReadPage: PROCEDURE [address: HANDLERawAddress] RETURNS [page:
          Page],
      RawWritePage: PROCEDURE [page: Page, address: HANDLERawAddress],
      RawReadBlock: PROCEDURE [address: HANDLERawAddress] RETURNS [block:
          Block],
      RawWriteBlock: PROCEDURE [block: Block, address: HANDLERawAddress],
      lupineDetails: PRIVATE REF LupineDetailsObject←NIL];

  LupineDetailsObject: PRIVATE TYPE;

 -- Definitions for the stubs.
 
 LupineProtocolVersion: PUBLIC VersionRange = [first: 1, last: 1];
 
 InterMdsCallsOnly: PUBLIC BOOLEAN = FALSE;

  ProcedureIndex: PRIVATE TYPE = MACHINE DEPENDENT {
      LupineUnusedIndex (0), LupineLastIndex (3),
      Input (4), Output (5), RawRead (6), RawWrite (7), RawReadPage (8),
      RawWritePage (9), RawReadBlock (10), RawWriteBlock (11)};

  SignalIndex: PRIVATE TYPE = MACHINE DEPENDENT {
      LupineUnusedIndex (0), LupineLastIndex (3),
      Error (4)};


END.  -- MultibusRpcControl.