SIC Analogue block control signals
Metal1, 3u wide, including fringe: 0.12pF/mm.
Gate is 12 e-4 pF/m2.
Name Signal type Gate load Length of E-W Nb Cells Gate Wire Total Rise Time
per block metal in block (pF) (pF) (pF) (ns)
Agc[0..2] dc 10 x 2 200um 64
nAgc0[0..2] dc 10 x 2 200um 64
T[0..3] dc 10 x 2 200um 64
nT0[0..3] dc 10 x 2 200um 64
(n)Reset1 pulse/0.8us 10 x 2 2.8mm 64 1.5 10.8+1.7 14.0
(n)Reset2 pulse/1.0us 100 x 2 3.2mm 64 15 12.3+1.7 29.0
(n)Store1 pulse/0.9us 20 x 2 2.6mm 64 3.0 10.0+1.7 14.7
(n)Store2 pulse/1.4us 10 x 2 1.9mm 64 1.5 7.3+1.7 10.5
(n)Set pulse/0.2us 2 x (10 x 2) 1.7mm 64 3.0 6.5+1.7 11.2
(n)IntRst pulse/0.1us 10 x 2 1.2mm 64 1.5 4.6+1.7 7.8
(n)ExtRst pulse/1.0us 30 x 2 1.1mm 64 4.6 4.2+1.7 10.5
SRCK pulse/100ns 35 x 2 0 64 5.4 1.7 7.1 4
SRLoad pulse/200ns 35 x 2 0 64 5.4 1.7 7.1 4
SRReset pulse/200ns 35 x 2 0 64 5.4 1.7 7.1 4
BitSelect pulse/200ns 53 x 2 0 64 8.1 1.7 9.8 5